Search found 2066 matches
- Mon Feb 27, 2023 3:10 pm
- Forum: General Discussion
- Topic: Help with pipe connection & terminology
- Replies: 14
- Views: 2905
Re: Help with pipe connection & terminology
When I come to problems like this and sourcing the right part is a problem or it takes too much of an effort, I am quick to go the route of using the machines I have to thread, rethread, turn, bore out or silver solder the pieces together. As a matter of fact, I was in a similar predicament 20 minut...
- Tue Feb 21, 2023 4:36 pm
- Forum: Live Steam
- Topic: Broken Taps
- Replies: 21
- Views: 4353
Re: Broken Taps
Just an idea. Since is a through hole, I would cut indentation on the tip of a dowel. As many indentations as the No of flutes and try to drive the tap out from the back. Less risk to bugger the hole.
- Sun Feb 12, 2023 7:20 am
- Forum: General Discussion
- Topic: $100 Mistake
- Replies: 11
- Views: 1490
Re: $100 Mistake
Kind of Johansson blocks on a slimming diet.
- Fri Feb 10, 2023 9:53 am
- Forum: General Discussion
- Topic: Mitutoyo Digital Caliper
- Replies: 23
- Views: 4187
Re: Mitutoyo Digital Caliper
Great. Thanks
- Fri Feb 10, 2023 8:56 am
- Forum: General Discussion
- Topic: Mitutoyo Digital Caliper
- Replies: 23
- Views: 4187
Re: Mitutoyo Digital Caliper
Thanks. Be interested to try the fix.
- Wed Feb 08, 2023 7:24 am
- Forum: The Junk Drawer
- Topic: Discouraged!
- Replies: 22
- Views: 6441
Re: Discouraged!
Harold a few comments on the nomenclator. What you call a doughnut (the one skewered by the big thick wire) is a Current Transformer. Is just a special transformer designed to have an output proportional to the current passing into the single wire. Is a safer method to provide a Shunt since it also ...
- Wed Feb 08, 2023 7:12 am
- Forum: The Junk Drawer
- Topic: Discouraged!
- Replies: 22
- Views: 6441
Re: Discouraged!
I am an electrical engineer, but the field is so vast I have no more that general knowledge outside my field of specialization. Is interesting that for some reason Lagging phase is to be avoided as destructive to the generator. If the current Lags the Voltage the load is seen as Inductive, meaning m...
- Tue Feb 07, 2023 3:59 pm
- Forum: The Junk Drawer
- Topic: Discouraged!
- Replies: 22
- Views: 6441
Re: Discouraged!
Why one need a KWAR meter to safely run a rotating generator?
I assume KVAR means Kilo Volt Amper Reactive
A generator is limited by VoltxAmpere which is called Apparent power.
I assume KVAR means Kilo Volt Amper Reactive
A generator is limited by VoltxAmpere which is called Apparent power.
- Tue Feb 07, 2023 2:15 pm
- Forum: General Discussion
- Topic: 5c or er40 collets?
- Replies: 12
- Views: 2959
Re: 5c or er40 collets?
One thing about changing ER collet is that usually it takes less Z axis movement.
- Mon Feb 06, 2023 7:59 am
- Forum: General Discussion
- Topic: 5c or er40 collets?
- Replies: 12
- Views: 2959
Re: 5c or er40 collets?
If you work both in metric and imperial and then some dimension that is neither You need a huge number of 5C collets.
I love my ER set. Use it with drill bits too, my Jacob chuck is gathering dust.
I love my ER set. Use it with drill bits too, my Jacob chuck is gathering dust.
- Mon Feb 06, 2023 7:53 am
- Forum: General Discussion
- Topic: Thread Locker shelf life
- Replies: 18
- Views: 2881
Re: Thread Locker shelf life
I think Harold said the final words on this subject and those apply to the general philosophy of life.
- Fri Feb 03, 2023 5:22 pm
- Forum: General Discussion
- Topic: Mitutoyo Digital Caliper
- Replies: 23
- Views: 4187
Re: Mitutoyo Digital Caliper
After dead batteries and one that require constant zero (it comes to life with 0.439) I switched to vernier type. I made a living in electronic but I am not a fan of commercial electronic.